Next  |  Prev  |  Up  |  Top  |  JOS Index  |  JOS Pubs  |  JOS Home  |  Search

Dolph-Chebyshev and Hamming Windows Compared


\begin{psfrags}\psfrag{freq}{$\omega T$\ (radians per sample)}\begin{center}
\epsfig{file=eps/chebHammingC.eps,width=6.5in} \\
\end{center}
\end{psfrags}

For the comparison, we set the ripple parameter for chebwin to $ 42$ dB:

window = [ chebwin(31,42)' zeros(1,1024-31) ];


Next  |  Prev  |  Up  |  Top  |  JOS Index  |  JOS Pubs  |  JOS Home  |  Search

[Comment on this page via email]

``FFT Windows'', by Julius O. Smith III and Bill Putnam, (From Lecture Overheads, Music 421).
Copyright © 2020-06-27 by Julius O. Smith III and Bill Putnam
Center for Computer Research in Music and Acoustics (CCRMA),   Stanford University